Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register

Indexing Metadata

Resolution of Dopamine in the Presence of Ascorbic Acid and Uric Acid by the Poly Oxalic Acid Modified Carbon Paste Electrode

DUBLINCOREMETADATA ITEM METADATA FOR THIS DOCUMENT
1TitleTitle of DocumentResolution of Dopamine in the Presence of Ascorbic Acid and Uric Acid by the Poly Oxalic Acid Modified Carbon Paste Electrode
2CreatorAuthor's name, affiliation, country P.JEEVAN JYOTI, K.GANGADHARA REDDY, V. PRABHAKER RAO, M. LAVANYA and G.MADHAVI*
Department of Chemistry, S.V.U. College of Sciences, Sri Venkateswara University, Tirupati-517502, Andhra Pradesh, India
3SubjectDicipline(s) Chemical Science
3SubjectKeywords Oxalic acid, Ascorbic acid, Uric acid, Dopamine, Cyclic Voltammetry, Differential pulse voltammetry
4DescriptionAbstract A novel poly oxalic acid carbon paste electrode was fabricated by electro polymerization process and characterized in this study. This poly oxalic acid modified carbon paste electrode by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) exhibited an excellent electro catalytic activity towards the resolution of ascorbic acid (AA), dopamine (DA) and uric acid (UA) compared with bare carbon paste electrode. The effect of pH range from 5.5 to 8.0 was studied and the redox peak was pH dependent with a slope of 60 mV/pH and from the regression coefficient of the effect of scan rate shows that the process is adsorption controlled. The DPV study of 6.2 to 131 μM concentration range of DA shows 6 μM detection limit. The oxidation potentials of AA, DA and UA at the poly oxalic acid modified carbon paste electrode was shifted slightly negatively and the peak currents were much larger than the bare carbon paste electrode. DPV was used for the simultaneous determination of AA, DA and UA in their mixture, and the peak potential separations between AA and DA, DA and UA, AA and UA were197 mV, 169 mV and 367 mV respectively. The limit of detection for AA, DA and UA were 0.93 mM, 7.4 μM and13 μM respectively. This Oxalic acid modified carbon paste electrode showed many merits in stability, sensitivity, facility, economy and also applicable for real sample analysis
5PublishersOrganizing agency, location WWW Publications, India
6Contributor Sponsor(s) -
7DateDate (YYYY-MM-DD) -
8TypeStatus & genre Peer-reviewed Article
8TypeType
9FormateFile Formate PDF
10IdentifierUniform Resource Identifier Click Here
10IdentifierDigital Object Identifier
11SourceJournal/conference title; vol., no. (Year)Chemical Science Transactions, Volume  4 , Number  (2), (2015)
12LanuguageEnglish=en en
13RelationSupp.files
14Coverage -
15CopyrightCopyright and permissions
Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register