Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register

Indexing Metadata

Method Development and Validation RP-HPLC Method for the Simultaneous Estimation of Levofloxacin Hemihydrate and Cefpodoxime Proxetil in Pharmaceutical Dosage Form

DUBLINCOREMETADATA ITEM METADATA FOR THIS DOCUMENT
1TitleTitle of DocumentMethod Development and Validation RP-HPLC Method for the Simultaneous Estimation of Levofloxacin Hemihydrate and Cefpodoxime Proxetil in Pharmaceutical Dosage Form
2CreatorAuthor's name, affiliation, country ANIL KUMAR VEERAGONI*, RANJEETH REDDY K, MALLADI SRINIVAS REDDY, CHILAGANI ARUN KUMAR, VASUDEVA MURTHY SINDGI and SHOBA RANI SATLA
Department of Pharmaceutical Analysis, Pathfinder Institute of Pharmacy Education and Research, Warangal-Telangana, India
Department of Pharmaceutical Analysis and Quality Assurance, Vaageswari College of Pharmacy, Karimnagar-505481, Telangana State, India
Jayamukhi College of Pharmacy, Narsampet Warangal, Telangana, India
Centre for Pharmaceutical Sciences, Institute of Science and Technology, JNTUH, Hyderabad, Telangana, India
3SubjectDicipline(s) Chemical Science
3SubjectKeywords High performance liquid chromatography, Gudcef-L, Levofloxacin hemihydrates, Cefpodoxime proxetil
4DescriptionAbstract A new simple, sensitive, accurate and precise method has been developed for the simultaneous estimation of Levofloxacin hemihydrate and Cefpodoxime proxetil in pharmaceutical dosage form by RP-HPLC. After optimization good chromatographic separation was achieved by isocratic mode with a mixture of K2HPO4 and methanol pH 8 in the ratio of 40:60 v/v as the mobile phase with YMC C18 (250 mm x 4.6 mm i.d x 5 μm) column as stationary phase at flow rate of 1mL/min and detection wavelength of 275 nm. The retention time of Levofloxacin hemihydrate and Cefpodoxime proxetil were found to be 2.8 and 3.9 min respectively. The linearity of this method was found in the concentration range of 250 μg/mL to 750 μg/mL for Levofloxacin hemihydrate and 200 μg/mL to 600 μg/mL for Cefpodoxime proxetil. The method was extensively validated according to ICH guidelines Q2B for Linearity, Range, Accuracy, Precision, Specificity and Robustness
5PublishersOrganizing agency, location WWW Publications, India
6Contributor Sponsor(s) -
7DateDate (YYYY-MM-DD) -
8TypeStatus & genre Peer-reviewed Article
8TypeType
9FormateFile Formate PDF
10IdentifierUniform Resource Identifier Click Here
10IdentifierDigital Object Identifier
11SourceJournal/conference title; vol., no. (Year)Chemical Science Transactions, Volume  5 , Number  (4), (2016)
12LanuguageEnglish=en en
13RelationSupp.files
14Coverage -
15CopyrightCopyright and permissions
Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register