Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register

Indexing Metadata

Electrochemical Behavior of Antidepressant Drug Vilazodone Hydrocholoride and its Determination at F-MWCNT-Nafion/GCE Sensor

DUBLINCOREMETADATA ITEM METADATA FOR THIS DOCUMENT
1TitleTitle of DocumentElectrochemical Behavior of Antidepressant Drug Vilazodone Hydrocholoride and its Determination at F-MWCNT-Nafion/GCE Sensor
2CreatorAuthor's name, affiliation, country MAHADEVA SINGH JAT, KALPANA, K. K. JHANKAL and D. K. SHARMA*
Electrochemical Sensor Research Laboratory, Department of Chemistry, University of Rajasthan, Jaipur (Rajasthan)-302004, India
3SubjectDicipline(s) Chemical Science
3SubjectKeywords Vilazodone hydrochloride, Antidepressant, Cyclic voltammetry, Glassy carbon electrode, Square wave voltammetry
4DescriptionAbstract A sensitive electroanalytical method for determination of vilazodone hydrocholoride in pharmaceutical formulation has been investigated on the basis of the enhanced electrochemical response at multi-walled carbon nanotubes modified glassy carbon electrode. Vilazodone gave one well-defined oxidation peak at 0.721 potential versus Ag/AgCl reference electrode in citrate buffer of pH 6.5. Oxidation process was irreversible and diffusion controlled. Diffusion coefficients (2.32x10-4 cm2/s and 6.45x10-4cm2/s), surface coverage (4.23x1033mol/cm2 and 98.01x10-3 mol/cm2) and heterogeneous rate constant (0.767s-1 and 1.241s-1) were calculated at both bare GCE and f-MWCNT-nafion modified GCE respectively. Increase values of said parameters proved that f-MWCNT-nafion, doped on bare GCE, positively catalyzed electron transfer between electrode-electrolyte interfaces. Based on CV, CPC and pH studies a oxidation mechanism was proposed involving 2H+/2e-. The proposed square wave voltammetric method shows linearity over the concentration range (0.2x10-5-3.6x10-4M). The achieved limits of detection (LOD) and quantification (LOQ) are 9.6x10-8 g/mL and 3.23x10-7 g/mL respectively. The proposed method was successfully employed for the assay of drug in bulk formulations, human blood and human urine samples.
5PublishersOrganizing agency, location WWW Publications, India
6Contributor Sponsor(s) -
7DateDate (YYYY-MM-DD) -
8TypeStatus & genre Peer-reviewed Article
8TypeType
9FormateFile Formate PDF
10IdentifierUniform Resource Identifier Click Here
10IdentifierDigital Object Identifier
11SourceJournal/conference title; vol., no. (Year)Chemical Science Transactions, Volume  8 , Number  (4), (2019)
12LanuguageEnglish=en en
13RelationSupp.files
14Coverage -
15CopyrightCopyright and permissions
Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access