Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register

Indexing Metadata

A Quantitative and Qualitative High Performance Liquid Chromatographic Determination of Aceclofenac Specified Impurity-B (Methyl[2-[(2, 6-dichlorophenyl)amino] phenyl]acetate) in Aceclofenac Bulk Drug

DUBLINCOREMETADATA ITEM METADATA FOR THIS DOCUMENT
1TitleTitle of DocumentA Quantitative and Qualitative High Performance Liquid Chromatographic Determination of Aceclofenac Specified Impurity-B (Methyl[2-[(2, 6-dichlorophenyl)amino] phenyl]acetate) in Aceclofenac Bulk Drug
2CreatorAuthor's name, affiliation, country P L. SOMASHEKAR, P N. SANJAY PAI and GOPALKRISHNA RAO
Department of Quality Assurance, Al-Ameen College of Pharmacy, Near Lalbagh Main Gate, Hosur Road, Bangalore -560027, India
Department of Pharmaceutical Chemistry, Goa College of Pharmacy, 18th June Road, Panaji, Goa- 403001, India
3SubjectDicipline(s) Chemical Science
3SubjectKeywords Aceclofenac, Aceclofenac impurity, HPLC method
4DescriptionAbstract Aceclofenac is a phenylacetic acid derivative with potent analgesic and anti-inflammatory properties and an improved gastro-intestinal tolerance. In the present study, a reversed-phase HPLC method was developed for analysis of aceclofenac and applied for detection and quantification of aceclofenac specified impurity-B (methyl[2-[(2, 6-dichlorophenyl)amino]phenyl]acetate) with UV detection in bulk drug. Aceclofenac and its impurity were separated using an acetonitrile-phosphate buffer (60:40) isocratic method with a flow rate of 1 mL/min and UV detection at 275 nm. The retention times for aceclofenac and its impurity were 3.0 min and 13.04 min respectively. The method was validated as per ICH guidelines. The calibration was linear over the range of 1-25 mcg/mL for aceclofenac and 1-20 mcg/mL for Aceclofenac impurity-B. The method showed excellent sensitivity (detection limit of 10 μg/mL) with good precision and accuracy. This sensitive and selective method can be used for detection and quantification of aceclofenac impurity-B in aceclofenac bulk drug in order to control and regulate process related impurity.
5PublishersOrganizing agency, location WWW Publications, India
6Contributor Sponsor(s) -
7DateDate (YYYY-MM-DD) -
8TypeStatus & genre Peer-reviewed Article
8TypeType
9FormateFile Formate PDF
10IdentifierUniform Resource Identifier Click Here
10IdentifierDigital Object Identifier
11SourceJournal/conference title; vol., no. (Year)Chemical Science Transactions, Volume  2 , Number  (4), (2013)
12LanuguageEnglish=en en
13RelationSupp.files
14Coverage -
15CopyrightCopyright and permissions
Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register