Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register

Indexing Metadata

Application of Validated Stability-Indicating HPLC Method in Stability Testing of Acetaminophen and Guaiphenesin Tablets

DUBLINCOREMETADATA ITEM METADATA FOR THIS DOCUMENT
1TitleTitle of DocumentApplication of Validated Stability-Indicating HPLC Method in Stability Testing of Acetaminophen and Guaiphenesin Tablets
2CreatorAuthor's name, affiliation, country RAJYALAKSHMI CHAVAKULA and C. RAMBABU
Department of Chemistry, Vishnu Institute of Technology, Vishnupur, Bhimavaram-534202, A.P, India
Department of Chemistry, Acharya Nagarjuna University, Nagarjunanagar, Guntur, 522510, A.P, India
3SubjectDicipline(s) Chemical Science
3SubjectKeywords Acetaminophen, Guaiphenesin, RPHPLC method, Validation, Stability studies
4DescriptionAbstract The aim of the work is to develop and validate the simple, fast and precise stability indicating high performance liquid chromatography method for the separation and quantification of acetaminophen and guaiphenesin in pharmaceutical dosage form. The quantification was carried out using Symmetry C18 (4.6x150 mm, 3.5 µm) enhanced polar selectivity column and mobile phase comprised of potassium dihydrogen phosphate buffer pH 2.5 and methanol in proportion of ratio 65:35v/v. The flow rate was mL/min and the effluent was monitored at 228 nm. The retention time of acetaminophen and guaiphenesin were 2.6 and 4.6 min respectively. Linearity of acetaminophen and guaiphenesin were in the range of
50 to 90 µg/mL and 30 to 55 µg/mL respectively with correlation coefficients 0.999. The percentage recoveries were 99.80% and 99.85% for acetaminophen and guaiphenesin respectively. There was complete separation of degradation peaks and analyte peaks, which demonstrate the specificity of assay method in the presence of its degradation products; it can be employed as a stability indicating one. Due to simplicity, rapidity and accuracy of the proposed Stability Indicating High Performance Liquid Chromatography method, it is used for analysis of stability samples of Acetaminophen and Guaiphenesin in quality control laboratories.
5PublishersOrganizing agency, location WWW Publications, India
6Contributor Sponsor(s) -
7DateDate (YYYY-MM-DD) -
8TypeStatus & genre Peer-reviewed Article
8TypeType
9FormateFile Formate PDF
10IdentifierUniform Resource Identifier Click Here
10IdentifierDigital Object Identifier
11SourceJournal/conference title; vol., no. (Year)Chemical Science Transactions, Volume  3 , Number  (1), (2014)
12LanuguageEnglish=en en
13RelationSupp.files
14Coverage -
15CopyrightCopyright and permissions
Chemical Science Transactions | Chem Sci Trans | CST | Online Chemistry Journal | Open Access
Home | Table of Contents | Submit an article | Subscribe | Login | Register